FAA Part 107 CertifiedDrone Photography · Video · Photogrammetry$2M Liability InsuredCalifornia · Metro Atlanta · South FloridaNDAA-Compliant LiDAR on Request for Federal WorkCheckpoint Report With Every LiDAR JobAI-Planned Flights · Pilot in Command
← Back to Blog

Measuring change between two surveys: detection limits, co-registration and DEMs of difference

November 23, 2026

Illustrative image: Measuring change between two surveys: detection limits, co-registration and DEMs of difference

Two surveys of the same ground give you a third surface: the difference. Subtract the old elevation from the new one, add up the cells, and you have a volume. The trouble is that every cell in that difference carries the error of both surveys.

This post shows how to tell real change from noise. It uses two public LiDAR datasets of the same ground near the Eaton Fire burn area, one flown before the fire and one after. The post-fire survey is the same one used in the Eaton Fire debris basin post; this post looks at a different basin. The method works the same for slope monitoring, stockpiles, basins and fill progress.

Why the difference is noisier than either survey

A difference inherits the uncertainty of both inputs. If each survey has an independent vertical error of sigma, the difference has an error of about 1.41 times sigma. That comes from adding variances: the square root of sigma squared plus sigma squared.

Surveyors want a confidence statement, not a standard deviation. The usual one is the level of detection at 95% confidence, or LoD95. Lague, Brodu and Leroux give the parametric form used in the M3C2 method:

LoD95 = 1.96 x ( sqrt( s1² / n1 + s2² / n2 ) + reg )

Here s1 and s2 are the local roughness of each surface, n1 and n2 are the number of points averaged, and reg is the registration error between the two surveys. Averaging many points shrinks the first term. It does nothing for reg. Lague and colleagues conclude that for high-precision scanners the error budget is dominated by registration error and surface roughness.

Table 1 applies the simple 1.96 x 1.41 x sigma rule to three published accuracy figures. The arithmetic is simple error propagation. It assumes independent errors and ignores registration.

Single-survey vertical errorSourceDifference, 1 sigmaDifference, 95%
4 cmDJI's L2 system spec at 150 m, measured in a DJI lab5.7 cm11.1 cm
7 cmTamimi and Toth, open road9.9 cm19.4 cm
21 cmTamimi and Toth, under dense canopy29.7 cm58.2 cm

Table 1. Detection limit implied by single-survey vertical error, assuming independent errors and no registration error. Treating a spec sheet value as a standard deviation is an assumption.

The takeaway: on these figures, a change of a few centimeters is below the noise floor of a LiDAR pair. Under canopy, even a change of half a meter can hide in the noise. Spec sheets are a starting point. The real number comes from your own data.

Measure the noise floor from ground that did not change

You can estimate the detection limit from the two surveys themselves. Pick ground that should not have moved: pavement, rock, ridgetops. Subtract one survey from the other there. Whatever difference you see is error, not change.

Here is what that looks like with real data. The pair is the USGS 3DEP project CA_LosAngeles_1_B23, a public-domain collection whose points in these windows carry GPS times from October 2023 to January 2024, and the NCALM post-fire survey, flown February 20 to 21, 2025 (CC BY 4.0). Caltech's Eaton Fire study used 2023 USGS airborne LiDAR as its pre-fire baseline and describes it as quality level 2, with vertical RMSE of 10 cm or better. The paper does not name the project. Treating CA_LosAngeles_1_B23 as that baseline is an assumption here, not a statement from the paper. Both datasets are airborne LiDAR, not drone data, but the logic is identical.

The comparison uses 1 m ground models built from the classified points in two 500 m windows:

  • Flat: developed foothill ground in Sierra Madre, median slope about 3 degrees.
  • Hill: the steep chaparral slopes around the Sierra Madre Dam debris basin, median slope about 42 degrees.

"Stable" cells meet two rules. Both surveys have ground returns in the cell and all eight neighbors, so interpolated gaps are excluded. And the cell sits on convex ground, above the mean of its surroundings, so channels and hollows where debris moves are excluded. Figure 1 shows the differences on those cells.

Overlaid log-scale histograms of elevation differences between two LiDAR surveys on stable ground. The flat-site histogram is a narrow spike within about 6 cm of zero. The hillslope histogram is broad, with its 95% detection limit near 59 cm.
Figure 1. Elevation difference, NCALM February 2025 minus USGS 3DEP, on stable-ground cells at two sites. Dashed lines mark the median offset plus or minus LoD95. The hillslope value is an upper bound on instrument noise, since it likely includes some real post-fire change. Data: USGS 3DEP CA_LosAngeles_1_B23 and NCALM CA25_Lamb. Built 2026-10-18.
SiteStable cellsMedian offsetRobust spread (NMAD)LoD95
Flat, developed34,655+0.6 cm1.7 cm6.3 cm
Hillslope, chaparral45,913-11.5 cm18 cm58.6 cm

Table 2. Stable-ground statistics from Figure 1. NMAD is 1.4826 times the median absolute deviation. LoD95 here is the 95th percentile of the absolute difference after removing the median offset, so it assumes no particular distribution.

The same two surveys give a detection limit of about 6 cm on the flat ground and at most 59 cm on the hillslope. Nothing about the sensors changed between sites. The terrain did, and the hillslope burned in between.

Why the hillslope is worse

Three things plausibly drive the gap. The first is geometry and the second is a general LiDAR limitation. The third is an inference from the dates.

  • Slope turns horizontal error into vertical error. This is geometry, not a measured result. On a 42 degree slope, a 20 cm horizontal misregistration shifts the surface about 18 cm vertically (20 cm times the tangent of 42 degrees). On flat ground the same shift costs almost nothing.
  • Ground under brush is hard to classify. Fewer points reach the ground under dense chaparral, and the classified surface can sit above the true ground. Tamimi and Toth found 21 cm under canopy against 7 cm in the open.
  • The "stable" hillslope is not fully stable. One survey is before the fire and one after. Burned ground can lose soil and ash. Some of that 59 cm is likely real change, so treat it as an upper bound on instrument noise, not a measure of it.

Caltech's own estimates fall between the two site values. They report a minimum detectable change at 95% confidence of 0.30 m between airborne and UAV LiDAR, and 0.17 m between two UAV datasets. They assumed about 5 cm of co-registration uncertainty in sparsely vegetated, sloped terrain.

One Texas surveyor with 23 years of experience put the limits of drone data plainly: "i don't know that the drone is going to be more accurate than traditional surveying methods but it's going to eliminate some of the systematic errors" (Daniel Cooper, 2:59, on a vendor channel). Systematic errors are the ones that survive averaging, and they are what co-registration is for.

Daniel Cooper, Texas surveyor, on drone data and systematic errors (vendor-hosted video). Third-party public video, not a Twinn Digital project. — SmartDrone

Co-registration: remove the shift before you subtract

Look at the hillslope row in Table 2. The median offset is -11.5 cm. A plane fitted to the stable cells also tilts by about 21 cm across the 500 m window from west to east. They most likely reflect how the two surveys sit relative to each other, though on burned ground part of the offset could be real lowering.

The offset matters because it multiplies by area. Figure 2 shows the difference map for the hill window before and after removing the offset and masking cells inside LoD95.

Two side-by-side difference maps of the Sierra Madre Dam window. The raw map is speckled with grey. After removing the offset and masking changes under 59 cm, only the large blue basin fill, a few channels and scattered grey patches remain.
Figure 2. Elevation change in a 500 m window around Sierra Madre Dam. Blue is gain, dark grey is loss. A: raw difference. B: median offset removed, cells within the LoD95 masked. Data: USGS 3DEP CA_LosAngeles_1_B23 and NCALM CA25_Lamb. Built 2026-10-18.

Figure 3 turns the same window into volumes. The window covers 250,000 m². An 11.5 cm offset over that area is 28,700 m³.

Bar chart in thousand cubic meters: raw net change +22.1, offset correction +28.7, net after co-registration +50.8, then gain above the detection limit +69.8, loss beyond it -15.5 and change within it -3.6.
Figure 3. Volume bookkeeping for the Figure 2 window. Removing the offset raises the net by 28,700 m³. Cells within the LoD95 contribute -3,600 m³. Data: USGS 3DEP CA_LosAngeles_1_B23 and NCALM CA25_Lamb. Built 2026-10-18.

Two caveats apply. First, a single shift fixes translation only. A tilt or rotation needs a fuller model. Caltech aligned ground-classified point clouds with iterative closest point (ICP) registration, which solves for rotation as well as shift. Second, you cannot tell from the data alone whether the stable-ground offset is a datum or control error, a vegetation artifact or real lowering. Independent checkpoints can settle it.

What anchors a repeat series

Stable-ground statistics work after the fact. A better job fixes the problem at capture.

  • Permanent control outside the change area. Monuments or targets on bedrock, pavement or structures that will not move, surveyed once and reused every epoch.
  • Independent checkpoints each epoch. ASPRS Edition 2 calls for no fewer than 30 checkpoints to assess vertical accuracy, reported as RMSEv. It adds that vegetated vertical accuracy is reported as found, not as pass or fail. A small site may not fit 30 points, and the standard has a special reporting statement for that case.
  • One datum, one geoid model, one grid. A change in geoid model between epochs can show up as fill or loss. The dataset above uses NAVD88 with GEOID18. Say so in the deliverable.
  • Same ground classification and cell size. If epoch two keeps low brush as ground and epoch one does not, the difference map shows vegetation, not terrain.

DEM of difference or M3C2?

The DEM of difference, or DoD, is the grid subtraction used above. It is simple, it produces volumes directly, and any GIS can do it. It works well on gently sloping ground such as graded pads, stockpile bases, basin floors and fill surfaces.

It struggles where the surface is steep or vertical, because it measures change along the vertical axis only. Walls, cut faces and steep embankments are better served by M3C2. Lague and colleagues designed it to compute the distance between two point clouds along the local surface normal, with a confidence interval for each measurement. It runs on point clouds without gridding, and they describe it as usable as an alternative to DEM differencing in simple two-dimensional cases too. They implemented it in the free software CloudCompare, as their paper notes.

A rough rule: use a DoD for volumes on open ground, M3C2 for faces and slope movement, and report the LoD95 for either.

Reading the map: threshold, then total

Once the offset is removed, mask cells inside the LoD95 before reading anything off the map. Then total gains and losses separately.

In the Figure 2 window, the largest connected area of gain above 3 m has 6,774 cells and totals 52,600 m³. It sits about 80 m from the basin location in Caltech's coordinate table. That is the same order as the 56,253 m³ of net change Caltech reports for Sierra Madre Dam (their Table 2). The intervals and footprints differ, so this is a plausibility check, not a validation.

The uncertainty depends on the footprint. As a bound, take the hillslope spread of 18 cm and assume it is a bias shared by every cell. Over the 6,774 m² basin footprint that is about 1,200 m³, or 2% of the fill. Over the whole 250,000 m² window the same bound is about 45,000 m³, nearly as large as the net change. The first is an inference from Table 2, not a measured error. The point stands: volume over a small, well-defined footprint is robust, and a window-wide net total is not.

Setting up a repeat series

If you plan to monitor a slope, basin, stockpile or fill over several visits, settle these before the first flight:

  1. The question and the threshold. What change matters, in centimeters or cubic yards? If it is below the expected LoD95, no survey method will answer it.
  2. Control and checkpoints. Which monuments anchor every epoch, and where are the independent checkpoints?
  3. Datum, geoid and grid. Write them once and reuse them.
  4. Processing. Same classification settings, same cell size, same interpolation.
  5. Reporting. Every change map ships with its stable-ground statistics, the offset applied and the LoD95 used.
  6. Seasonal timing. Vegetation state changes the ground surface. Compare like with like where you can.

For design or permit use, the change surfaces and volumes need a licensee in responsible charge. In California that is a PLS, or a civil engineer legally authorized to practice land surveying. In Georgia it is a PLS. In Florida it is a PSM. Twinn does not stamp.

One practical next step

Pick one site you survey more than once. Take the last two epochs and subtract them on ground you know did not move, such as a parking lot, a pad or a concrete channel. Record the median offset and the 95th percentile of the absolute difference. That is the number every change claim on that site has to beat. If you do not have two epochs yet, the same exercise works on checkpoints.

If you are planning a repeat series for a licensed partner to sign, see Twinn Digital for surveyors and engineers.

Ready to See Your Terrain?

Get a quote built around your project

Whether you manage farmland, watersheds, municipal infrastructure, or development sites — tell us about your site and we'll prepare a scope and estimate around the required outputs and schedule.

Get a quote